• Skip to primary navigation
  • Skip to main content
Imesa

Imesa

electrical engineering

  • Products
    • Medium voltage primary distribution electrical panels
    • Medium voltage secondary distribution electrical panels
    • Low voltage electrical panels
    • Automation and SCADA
    • Shore connection solution
  • Sectors
    • Industry
    • Marine & Offshore
    • Power & energy
    • OIL & GAS
    • TRANSPORT
  • Service
    • Services
    • After-sales assistance
  • Company
    • Certifications
    • Who we are
    • Our history
    • Work with us
  • Sustainability
    • Environment and land
    • People and governance
  • Downloads
    • Publications
    • Catalogues
    • Manuals
    • Company profile
    • Sustainability report
    • Code of ethics
    • Certifications
  • Contacts
    • Contacts
    • Agents
    • Work with us
  • Magazine
  • EN
    • EN
    • IT

ENEL approved Secondary Cabin GSCM004

The secondary medium-voltage cabins approved according the ENEL specification GSCM004are designed and built in compliance with the distributor’s technical specifications, ensuring the highest levels of safety, reliability, and continuity of service in electricity distribution. Each solution is developed to guarantee ease of installation, accessibility for operation and maintenance activities, and full compatibility with ENEL networks.

Imesa switchgears are built using certified materials and high-quality components, subjected to rigorous inspections and testing, and can be supplied in various configurations depending on application requirements and the specifications of the grid operator.

  • Vacuum circuit breakers.
  • Air-insulated earthing switches.
  • Air-insulated rotary line disconnectors.
  • Dry-air-insulated switch disconnectors.

Electrical and construction characteristics

Rated Voltage (Ur)24 kV
Power-frequency withstand voltage to earth (Ud)50 kV
Lightning impulse withstand voltage to earth and between phases (Up)125 kV
Rated frequency (fr)50 Hz
Rated thermal current of main busbars (lr)630 A
Rated short-time withstand current (lk)16 kA
Peak short-time withstand current (lp)40 kA
Rated short-circuit duration (tk)1 s
Internal arc classificationIAC
Accessibility typeAFL
Arc test current (la)16 kA
Arc test duration (ta)1 s
Degree of protection (excluding operating mechanisms)IP3X
Rated filling pressure of insulating gas (abs.)1,1 bar
Minimum filling pressure of insulating gas (abs.)1,0 bar
Annual relative leakage rate0,1 %

Main features of the GSCM004 Enel approved switchgear

  • ENEL approval for secondary medium-voltage substations
  • Compact structure for optimized installation space
  • Configuration designed for easy integration into the distribution network
  • High safety standards for operators and equipment
  • Version with internal arc classification (AFL)
  • Protection degree IP3X
  • Suitable for wall-mounted installation
  • Ease of installation, operation, and maintenance
  • Product certifications, type tests, and acceptance tests in accordance with ENEL specifications.

Fields of application

The ENEL-specific GSCM004 switchgears are used in secondary medium-voltage electrical distribution and can be easily installed in substations to manage and protect supply lines, metering equipment, and transformers.

  • Industrial plants
  • Infrastructure and public services: hospitals, airports, railway stations, water treatment plants, telecommunications networks, and strategic infrastructure.
  • Civil and commercial construction: shopping centers, residential complexes, offices, hospitality facilities, and business premises.
  • Energy systems and utilities: local distribution networks, energy management and control systems, applications for distribution companies and multi-utilities.
  • New connections and grid upgrades: construction of new connections to the ENEL network or adaptation of existing systems for power increases or regulatory updates.

Standard references

The equipment complies with the following standards:

  • GSCM004, Rev.1 – 10/2022
  • CEI EN 62271-200, Ed. 3 – 05/2021
  • IEC 62271-1, Ed.2 – 07/2017
  • IEC 62271-102, Ed.2 – 05/2018
  • DMI 031082, Ed.3 dated 18/06/2014
  • DMI 031015, Ed.4 dated 14/07/2015
  • DMI 031052, Ed.3 DATED 28/02/2014

In particular, the ENEL approved switchgears can be classified as:

  • Service Continuity: LSC2A
  • Diaphragm Classification: PM

Internal arc: IAC AFL (on request only)

More info
pdf catalogue

    Contact information

    Company data

    Plant data

    Request



    Similar products

    Minifluor

    Minifluor

    Scopri
    JESAIR® – the new SF6 free air insulated switchgear

    JESAIR® – the new SF6 free air insulated switchgear

    Scopri

    Contattaci

    Contatta il nostro team per informazioni sui prodotti o richieste commerciali

    Contatti

    I.M.E.S.A. S.p.a.

    Via G. di Vittorio 14, Zona Industriale ZIPA, Jesi (AN) – Italy

    Phone: (+39) 0731 211034

    Email: info@imesaspa.com

    • X
    • LinkedIn
    • YouTube
    • Certifications
    • Code of ethics
    • Sustainability report
    • Reporting of offenses
    • General terms and conditions of supply
    • Contacts
    • Agents
    • FAQ
    • Work with us
    • Organization

    Copyright © 2026 I.M.E.S.A. S.p.a. – Via G. di Vittorio, 14 – 60035 Jesi (AN) – Italy Social Capital €1.612.000 i.v. – Reg. Impr. AN/C.F./P.Iva 00155630429

    Manage consent
    Per fornire le migliori esperienze, utilizziamo tecnologie come i cookie per memorizzare e/o accedere alle informazioni del dispositivo. Il consenso a queste tecnologie ci permetterà di elaborare dati come il comportamento di navigazione o ID unici su questo sito. Non acconsentire o ritirare il consenso può influire negativamente su alcune caratteristiche e funzioni.
    Funzionale Always active
    L'archiviazione tecnica o l'accesso sono strettamente necessari al fine legittimo di consentire l'uso di un servizio specifico esplicitamente richiesto dall'abbonato o dall'utente, o al solo scopo di effettuare la trasmissione di una comunicazione su una rete di comunicazione elettronica.
    Preferenze
    L'archiviazione tecnica o l'accesso sono necessari per lo scopo legittimo di memorizzare le preferenze che non sono richieste dall'abbonato o dall'utente.
    Statistiche
    L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici. L'archiviazione tecnica o l'accesso che viene utilizzato esclusivamente per scopi statistici anonimi. Senza un mandato di comparizione, una conformità volontaria da parte del vostro Fornitore di Servizi Internet, o ulteriori registrazioni da parte di terzi, le informazioni memorizzate o recuperate per questo scopo da sole non possono di solito essere utilizzate per l'identificazione.
    Marketing
    L'archiviazione tecnica o l'accesso sono necessari per creare profili di utenti per inviare pubblicità, o per tracciare l'utente su un sito web o su diversi siti web per scopi di marketing simili.
    • Manage options
    • Manage services
    • Manage {vendor_count} vendors
    • Read more about these purposes
    Visualizza preferenze
    • {title}
    • {title}
    • {title}